I/O ports and slots | 24 RJ-45 autosensing 10/100 PoE+ ports (IEEE 802.3 Type 10BASE-T, IEEE 802.3u Type
100BASE-TX, IEEE 802.3at PoE+); Media Type: Auto-MDIX; Duplex: half or full
2 autosensing 10/100/1000 ports (IEEE 802.3 Type 10BASE-T, IEEE 802.3u Type 100BASE-TX,
IEEE 802.3ab Type 1000BASE-T); Duplex: 10BASE-T/100BASE-TX: half or full; 1000BASE-T: full
only
2 open mini-GBIC (SFP) slots |
Additional ports and slots | s 1 RJ-45 serial console port |
Physical
characteristics |
Dimensions |
17.44(w) x 14.5(d) x 1.73(h) in (44.3 x 36.83 x 4.39 cm) (1U height) |
Weight |
10.67 lb (4.84 kg) shipping weight |
|
Memory and processor |
Processor |
Power PC FreeScale 8313 @ 400 MHz, 512 MB flash; Packet buffer size:
1 MB, 512 MB SDRAM, 4 MB flash ROM |
|
Mounting and enclosure | Mounts in an EIA-standard 19 in. telco rack or equipment cabinet (hardware included); Horizontal surface mounting only |
Performance |
IPv6 Ready certified |
|
100 Mbps Latency |
< 8.3 µs (LIFO |
1000 Mbps Latency |
< 2.9 µs (LIFO) |
Throughput |
up to 9.5 Mpps |
Routing/Switching capacity |
12.8 Gbps |
MAC address table size |
16000 entries |
|
Environment |
Operating temperature |
32°F to 131°F (0°C to 55°C) |
Operating relative humidity |
15% to 95%, noncondensing |
Nonoperating/Storage temperature |
-40°F to 158°F (-40°C to 70°C) |
Nonoperating/Storage relative humidity |
15% to 95%, noncondensing |
Altitude |
up to 10,000 ft (3 km) |
Acoustic |
Power: 34.0 dB, Pressure: 25.3 dB |
|
Electrical characteristics |
Achieved Miercom Certified Green Award |
|
Frequency |
50/60Hz |
Maximum heat dissipation |
270 BTU/hr (284.85 kJ/hr), (switch only: 270 BTU/hr; combined switch
+ max. PoE devices: 1751 BTU/hr) |
Voltage |
100 - 127 / 200 - 240 VAC, rated |
Current |
4.9/2.5 A |
Maximum power rating |
39.5 W |
Idle Power |
22.8 W |
Idle Power |
382 W |
|
Safety | EN 60950/IEC 60950; CAN/CSA 22.2 No. 60950; EN 60825; UL 60950 |
Emissions | FCC Class A; VCCI Class A; EN 55022/CISPR 22 Class A |
Immunity |
EN |
EN 55024, CISPR 24 |
ESD |
IEC 61000-4-2 |
Radiated |
IEC 61000-4-3 |
EFT/Burst |
IEC 61000-4-4 |
Surge |
IEC 61000-4-5 |
Conducted |
IEC 61000-4-6 |
Power frequency magnetic field |
IEC 61000-4-8 |
Voltage dips and interruptions |
IEC 61000-4-11 |
Harmonics |
IEC 61000-3-2 |
Flicker |
IEC 61000-3-3 |
|
Management | Aruba AirWave Network Management; IMC – Intelligent Management Center; Command-line
interface; Web browser |
Services | Refer to the Hewlett Packard Enterprise website at http://www.hpe.com/networking/services for
details on the service-level descriptions and product numbers. For details about services and
response times in your area, please contact your local Hewlett Packard Enterprise sales office. |
| |